 =====USRP Calibration Procedure===== =====USRP Calibration Procedure=====
  
-To calibrate the USRP, follow the steps provided below.\\ +To calibrate the USRP, follow the steps provided below. 
-In the "​USRP"​ tab:\\ + 
-  * Check the "​Conducted connection"​ box; \\ +In the "​USRP"​ tab: 
-  * Define the corresponding values in the "USRP Cal Facrotor, dB" and "​Attenuator,​ dB" fields, set "Cable Length, m" to 0, and then select the required "​Spoofing Mode."\\+  * Check the "​Conducted connection"​ box;  
 +  * Define the corresponding values in the "**USRP Cal Facrotor, dB**" and "**Attenuator, dB**" fields, set "**Cable Length, m**" to **0**, and then select the required "​Spoofing Mode;"
  
 {{:​gp_simulator:​gp-simulator_usrp_calibration.png?​600|}} {{:​gp_simulator:​gp-simulator_usrp_calibration.png?​600|}}
Line 10: Line 11:
 \\ \\
  
-  * Connect RF outlet ​of the USRP to the spectrum analyzer or RF power meter. When using the spectrum analyzer, we recommend ​setting its CF to 1575.42 MHz, bandwidth to 10 MHz, and switch ​on the power measurement mode;  +  * Connect RF port of the USRP to the spectrum analyzer or RF power meter. When using the spectrum analyzer, we recommend ​set **CF** to **1575.42 MHz****bandwidth** to **10 MHz**, and switching ​on the power measurement mode;  
-  * Set "DUT input power, dBm" to "-20 dBm" respectively;​ +  * Set "**DUT input power, dBm**" to "**-20 dBm**" respectively;​ 
-  * Click on the  "Scenario ​Start" button to finish.+  * Click on the "​Start ​Scenario" button to finish;
  
 {{:​gp_simulator:​gp-simulator_usrp_start_calibration.png?​600|}} {{:​gp_simulator:​gp-simulator_usrp_start_calibration.png?​600|}}